500cc Container MEASURE & MIXING CHART
Volume of Catalyst to be used with RAYPLEX Gel Coat
CAT % |
#CC |
<18C |
21C |
>30C |
Gel Time |
Gel Time |
Gel Time |
||
0.50% |
2.5 |
XX |
44 |
31 |
0.75% |
3.75 |
XX |
26 |
19 |
1.00% |
5 |
30 |
21 |
12 |
1.25% |
3.75 |
24 |
16 |
ZZ |
1.50% |
7.5 |
21 |
13 |
ZZ |
2.00% |
10 |
18 |
10 |
ZZ |
XX= Poor Cure |
ZZ= Shrinkage- High Heat |
Never catalyze More than 2%
If the temp is below 70F/ 21C never go below 1% Catalyst
If the temp is above 80F/ 30C never go above 1% Catalyst
Example: Fill the container with gelcoat or resin almost to the top. Next draw 1 cc of catalyst into the syringe. Add to the Gelcoat and mix well. This will give you About 21 minutes of working time.